HERO Test-Ordnance Threat of Electromagnetic Radiation

MIL-STD-464 A/B/C

HERO Test - Hazards of Electromagnetic Radiation to Ordnance is a test conducted to determine the effect of electromagnetic radiation on military ammunition. HERO Testing - Ordnance Threat of Electromagnetic Radiation is critical to ensuring compliance of military devices with electromagnetic compatibility requirements and the safety of military ordnance.

HERO-Electromagnetic Radiation Ammunition Threat Test is conducted according to international standards. The most common among these standards are known as MIL-STD-464 (US Department of Defense Standard) and STANAG 4439 (NATO Standard).

The MIL-STD-464 standard defines electromagnetic compatibility requirements and specifies how to perform electromagnetic compatibility tests. It also defines the conditions required to conduct HERO-Electromagnetic Radiation Munitions Threat Testing. The MIL-STD-464 standard is used for both the design and testing of electromagnetically compatible devices.

STANAG 4439 is a standard adopted by NATO countries. The STANAG 4439 standard defines the basic principles of electromagnetic compatibility and how to perform HERO-Electromagnetic Radiation Munitions Threat Testing. It also specifies the testing procedures required to evaluate the electromagnetic compatibility of military munitions.

HERO-Ordnance Threat Testing of Electromagnetic Radiation is critical to electromagnetic compatibility requirements. Thanks to these tests, the electromagnetic compatibility of military devices is ensured and the safety of military ammunition is protected.

Within the scope of our STEST facility located in Ankara, which is an organization accredited by TURKAK, HERO Test - Electromagnetic Radiation on Ammunition in the A/B/C versions of the MIL-STD-464 standard in accordance with the TS EN ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories Standard. We are realizing the threat.
In order to increase the quality and reliability of your products, you can contact us for your Environmental, EMI/EMC and ATP Testing needs.

EMI/EMC Test Chambers Features

 

 

  Test Room 1 Test Room 2 Measurement unit
Width 6850 13000 mm
Size 5900 10000 mm
Height 3800 9000 mm
Door Dimension 1000x2000 4200x4750 mm
Turntable Diameter - 6 m
Turntable Load Carrying Capacity - 70 ton
Reflection Semi Anti-Reflective Semi Anti-Reflective  

Standards

  • MIL-STD-464A
  • MIL-STD-464B
  • MIL-STD-464C
CONTACT BY EMAIL