MIL-STD-461 E/F/G

 The first version of the MIL-STD-461 Standard, developed by the United States (US) Department of Defense, was published in 1967 and became the basic EMC standard for Electromagnetic Compatibility (EMC) qualification testing of military devices. The MIL-STD-461 standard has become the basis of many industrial and commercial applications over time, and this standard covers all areas of the army, including land, air and sea. MIL-STD-461 specifies interface and related verification requirements for the control of electromagnetic interference (EMI) emission and (EMC) susceptibility characteristics of electronic, electrical, and electromechanical equipment and subsystems. Such equipment and subsystems may be used independently or as an integral part of other subsystems or systems.

The most current requirement for MIL-STD-461 testing is the MIL-STD-461G procedure. However, E and F procedures are also applied in our facility. 

MIL-STD-461 tests include various test procedures to evaluate resistance to electromagnetic interference and radio frequency (RF) interference. These tests may include a variety of tests such as conductive and non-conductive radiation, conductive and non-conductive emissions, radio frequency (RF) conductivity tests, and transmission modulation evaluations.

According to the MIL-STD-461E/F/G Military test standard, the emissions of the electronic device are controlled by measuring the transmission and antenna path, and by applying electromagnetic interference to the device via external transmission and antenna, and by observing the effects on the device. It mainly covers the following tests:

• Measuring emission levels from an electrical or electronic product interacting with other electrical or electronic products

• The ability of electrical or electronic products to operate in situations where other electrical or electronic products are nearby (immunity)

MIL-STD-461 EMISSIONS AND IMMUNE TEST REQUIREMENTS MATRIX UNDER THE STANDARD

Tests Applied in MIL-STD-461 Standard

 

List of various versions of the standard, from the original MIL STD 461 to MIL STD 461G:
MIL-STD-461 (July 1967)
MIL-STD-461A (August 1968)
MIL-STD-461B (April 1980)
MIL-STD-461C (August 1986)
MIL-STD-461D (January 1993)
MIL-STD-461E (August 1999)
MIL-STD-461F (December 2007)
MIL-STD-461G (December 2015)

Within the scope of our STEST facility located in Ankara, which is an organization accredited by TURKAK, we carry out the tests in the E/F/G Versions of the MIL-STD-461 standard in accordance with the TS EN ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories Standard.
In order to increase the quality and reliability of your products, you can contact us for your Environmental, EMI/EMC and ATP Testing needs.

CONTACT BY EMAIL

info@stest.com.tr

VOICE COMMUNICATION

+90 (312) 905 06 90


STANDART KONTROL VE TEST HİZMETLERİ A.Ş.