RS103 Test (Radiated Susceptibility Electric Field 10KHz–40GHz)

MIL-STD-461 E/F/G

EMI/EMC Tests

rs103
RS103 Test (Radiated Susceptibility Electric Field 10KHz–40GHz)

Products that are used in the military, civil and automotive fields and contain electrical and electronic equipment in their production are subjected to electromagnetic compatibility tests before being put on the market. RS103 Test (Radiated Susceptibility, Electric Field 10KHz–40GHz) performed within the scope of MIL-STD-461 standard is one of the most important of these tests. For each product group, a jamming signal is generally sent via the antenna to the tested equipment, and this equipment must continue to operate within the limit values declared by the manufacturer of the tested product.

The RS103 Test (Radiated Susceptibility, Electric Field 10KHz–40GHz) requirement applies to equipment and subsystem enclosures and all interconnected cables. The required frequency range for RS103 Test (Radiated Susceptibility, Electric Field 10KHz–40GHz) is as follows: 2 MHz to 30 MHz frequency range for military ships, military aircraft including flight line, navy ships excluding aircraft and optionally for other equipment, 30 The range from MHz to 1 GHz can be realized for all of these, the range from 1 GHz to 18 GHz can also be realized for all of these, and the range from 18 GHz to 40 GHz can be achieved optionally. Frequency range optionals for RS103 Test (Radiated Susceptibility, Electric Field 10KHz–40GHz) are only required if specified in the supply specification.
The purpose of the RS103 Test (Radiated Susceptibility, Electric Field 10KHz–40GHz) is to verify the ability of the equipment and associated cabling under test to withstand electric fields.

Within the scope of our STEST facility located in Ankara, which is an organization accredited by TURKAK, RS103 Test (Radiation Susceptibility) in the E/F/G versions of the MIL-STD-461 standard in accordance with the TS EN ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories Standard. , Electric Field 10KHz–40GHz).
In order to increase the quality and reliability of your products, you can contact us for your Environmental, EMI/EMC and ATP Testing needs.

EMI/EMC Test Chambers Features

 

 

  Test Room 1 Test Room 2 Measurement unit
Width 6850 13000 mm
Size 5900 10000 mm
Height 3800 9000 mm
Door Dimension 1000x2000 4200x4750 mm
Turntable Diameter - 6 m
Turntable Load Carrying Capacity - 70 ton
Reflection Semi Anti-Reflective Semi Anti-Reflective  

Standards

  • MIL-STD-461E
  • MIL-STD-461F
  • MIL-STD-461G
CONTACT BY EMAIL

info@stest.com.tr

VOICE COMMUNICATION

+90 (312) 905 06 90


STANDART KONTROL VE TEST HİZMETLERİ A.Ş.