RE102 Test (Radiated Emissions Electric Field 10 kHz–40 GHz)

MIL-STD-461 E/F/G

EMI/EMC Tests

re102
RE102 Test (Radiated Emissions Electric Field 10 kHz–40 GHz)

RE102 Test (Radiated Emissions, Electric Field, 10kHz–40GHz) conducted within the scope of MIL-STD-461 standard, just like the RE101 test, is an electrical or electronic test for electrical, electronic and electromechanical devices designed for use in military systems and devices used in the subsystems of these devices. It offers a test method to measure unwanted signals emitted into the air from the device and the cables on it. Such uncontrolled signals are connected to other equipment cables or may affect the equipment chassis and internal conductors. These unwanted signals have the potential to induce current in equipment conductors and may cause harmful interference.

The RE102 Test (Radiated Emissions, Electric Field, 10kHz–40GHz) is performed to determine whether emissions are classified as narrowband or broadband. The limits allow broadband emissions to be higher in amplitude. Because this type of noise affects human senses better.

RE102 Test (Radiated Emissions, Electric Field, 10kHz–40GHz) requirements apply to electric field emissions from the equipment and associated cables under test. The primary purpose of the requirements is to protect sensitive receivers from interference from antennas and coupled antennas associated with the receiver.
The RE102 Test (Radiated Emissions, Electric Field, 10kHz–40GHz) method focuses on topics such as radiated emissions and electric field.
Frequency range requirements for RE102 Test (Radiated Emissions, Electric Field, 10kHz–40GHz) are as follows: land vehicles 2 MHz to 18 GHz, ships 10 kHz to 18 GHz, submarines 10 kHz to 18 GHz, navy aircraft 10 These ranges between kHz to 18 Ghz, air force aircraft 2 MHz to 18 GHz are required, and testing can be carried out at different desired ranges.

Within the scope of our STEST facility located in Ankara, which is an organization accredited by TURKAK, RE102 Test (Emissions by Radiation) in the E/F/G versions of the MIL-STD-461 standard in accordance with the TS EN ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories Standard. , Electric Field, 10kHz–40GHz).
In order to increase the quality and reliability of your products, you can contact us for your Environmental, EMI/EMC and ATP Testing needs.

EMI/EMC Test Chambers Features

 

 

  Test Room 1 Test Room 2 Measurement unit
Width 6850 13000 mm
Size 5900 10000 mm
Height 3800 9000 mm
Door Dimension 1000x2000 4200x4750 mm
Turntable Diameter - 6 m
Turntable Load Carrying Capacity - 70 ton
Reflection Semi Anti-Reflective Semi Anti-Reflective  

Standards

  • MIL-STD-461E
  • MIL-STD-461F
  • MIL-STD-461G
CONTACT BY EMAIL

info@stest.com.tr

VOICE COMMUNICATION

+90 (312) 905 06 90


STANDART KONTROL VE TEST HİZMETLERİ A.Ş.