CS116 Test (Sensitivity Sinusoid Transitions Cables 10 kHz-100 MHz)
MIL-STD-461 E/F/G
EMI/EMC Tests
CS116 Test (Susceptibility by Conductivity, Suppressed Sinusoid Transitions, Cables and Power Lines, 10kHz-100MHz) conducted within the scope of the MIL-STD-461 standard is used to evaluate electrical, electronic and electromechanical devices and systems of these devices designed for use in military systems, including all connection cables. It is implemented in its subsystems.
CS116 Test (Susceptibility via Conductivity, Suppressed Sinusoid Transitions, Cables and Power Lines, 10kHz-100MHz) requirements also apply to surface ship and submarine subsystems and suppliers of equipment for these systems.
During the CS116 Test (Susceptibility through Conductivity, Dumped Sinusoidal Transitions, Cables and Power Lines, 10kHz-100MHz), a Dumped Sinusoidal Signal is applied to the device being tested. In these tests, to verify the ability of the cables and power cables associated with the equipment under test to withstand moist sinusoidal transients, the transient effect produced by the pulse generator is applied individually to the cable bundles of the device under test directly with current injection probes.
During the CS116 Test (Susceptibility through Conductivity, Suppressed Sinusoid Transitions, Cables and Power Lines, 10kHz-100MHz), the pulse applied during the test is observed on the oscilloscope using current monitor probes. CS116 Testing (Susceptibility via Conductivity, Suppressed Sinusoidal Transients, Cables and Power Lines, 10kHz-100MHz) covers topics such as conducted susceptibility, bulk cable injection, and damped sinusoidal transients. However, power returns and neutrals do not need to be tested individually.
CS116 Testing (Susceptibility via Conductivity, Suppressed Sinusoidal Transients, Cables and Power Lines, 10kHz-100MHz) also parallels the following two Standards:
• IEC 61000-4-12 Electromagnetic compatibility (EMC) - Part 4: Testing and measurement techniques - Part 12: Oscillating waves immunity test
• IEC 61000-4-25 Electromagnetic compatibility and radio spectrum matters (ERM) - Part 4-25: HEMP immunity test methods for devices and systems
Within the scope of our STEST facility located in Ankara, which is an organization accredited by TURKAK, we conduct CS116 Test (Susceptibility through Conductivity) in the E/F/G versions of the MIL-STD-461 standard in accordance with the TS EN ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories Standard. , Suppressed Sinusoid Transitions, Cables and Power Lines, 10kHz-100MHz).
In order to increase the quality and reliability of your products, you can contact us for your Environmental, EMI/EMC and ATP Testing needs.
EMI/EMC Test Chambers Features
Test Room 1 | Test Room 2 | Measurement unit | |
Width | 6850 | 13000 | mm |
Size | 5900 | 10000 | mm |
Height | 3800 | 9000 | mm |
Door Dimension | 1000x2000 | 4200x4750 | mm |
Turntable Diameter | - | 6 | m |
Turntable Load Carrying Capacity | - | 70 | ton |
Reflection | Semi Anti-Reflective | Semi Anti-Reflective |
Standards
- MIL-STD-461E
- MIL-STD-461F
- MIL-STD-461G