Low Temperature Test

 
MIL-STD-810 F/G/H — RTCA DO 160 G

Low Temperature Test is performed to determine the resistance of the tested sample to lower temperatures than natural environmental conditions. The sample placed in the test cabin is kept for an appropriate period of time under low temperature conditions that will be encountered in real use and/or storage conditions. Low throughout the period of use at temperature Materials or equipment that need to be used in an environment are evaluated according to this test method.

As with the high temperature method (Method 501.5), manufacturers generally conduct low temperature tests in accordance with the MIL-STD-810G Method 502.5 standard to ensure that the devices operate between a maximum of 0 and 50 degrees. Likewise, there are two procedures within the scope of this standard: storage and operating test.

All types of air conditioning cabins that meet the technical specifications military and tests can be carried out in accordance with civil standards. Tests are carried out in accordance with MIL STD 810, RTCA DO 160 G, especially in the work area.

In order to perform functional tests during testing; In order to prevent air entry/exit, all interfaces of the sample to be tested (communication, power cables, etc.) are removed to the laboratory environment through a hermetic passage through the side ports of our Low Temperature Test Cabinet.

Standards and Methods

  • MIL-STD-810F Method 502.4
  • MIL-STD-810G Method 502.5
  • MIL-STD-810H Method 502.7

Within the scope of our STEST facility located in Ankara, which is an organization accredited by TURKAK, LOW TEMPERATURE TEST MIL-STD-810G Method 502.5 and MIL-STD-810H Method in accordance with TS EN ISO/IEC 17025 General Requirements for the Competence of Testing and Calibration Laboratories Standard. We carry out tests accredited according to the 502.7 standard. In order to increase the quality and reliability of your products, you can contact us for your Environmental, EMI/EMC and ATP Testing needs.

Enviromental Test Chamber Specifications

 

 

  Drive-In 1 Drive-In 2 Drive-In 3 Drive-In 4 Drive-In 5 Drive-In 6  Measurement unit
Width 6000 6000 9500 12000 15500 21500 mm
Size 4900 4900 4900 4900 4900 4900 mm
Height 4000 4000 4000 4000 4000 4000 mm
Humidity Change Range %20 RH ile %99 RH %20 RH ile %99 RH %20 RH ile %99 RH %20 RH ile %99 RH %20 RH ile %99 RH %20 RH ile %99 RH %
Temperature Change Rate 3°C/minute (max) 3°C/minute (max) 3°C/minute (max) 3°C/minute (max) 3°C/minute (max) 3°C/minute (max) °C
Minimum Temperature - 45 °C - 45 °C - 45 °C - 45 °C - 45 °C - 45 °C °C
Maximum Temperature + 80 °C + 80 °C + 80 °C + 80 °C + 80 °C + 80 °C °C

 

 

  Air Conditioning Chamber 1 Air Conditioning Camber 2  Measurement unit
Width 1000 2600 mm
Size 1000 2600 mm
Height 1000 2000 mm
Humidity Change Range %20 RH ile %99 RH %20 RH ile %99 RH %
Temperature Change Rate 3°C/minute (max) 3°C/minute (max) °C
Minimum Temperature - 76 °C - 65 °C °C
Maximum Temperature + 150 °C + 80 °C °C
CONTACT BY EMAIL

info@stest.com.tr

VOICE COMMUNICATION

+90 (312) 905 06 90


STANDART KONTROL VE TEST HİZMETLERİ A.Ş.