STEST

RE101 TEST

STEST has been accredited by TURKAK within this scope since 2021.
TURKAK Accreditation Certificate

TURKAK Accredited Testing and Verification

STEST is accredited by the Turkish Accreditation Institution (TURKAK) and carries out its testing and verification activities in an independent, competent, and impartial manner in compliance with national and international standards.

TURKAK Accredited Competent Laboratory International Recognition
Low-Frequency Magnetic Field Emissions Verification in Accordance with MIL-STD-461

RE101 Test (Radiated Emissions, Magnetic Field, 30Hz–100kHz)

The RE101 test, conducted within the scope of MIL-STD-461, is intended to evaluate the low-frequency magnetic field emissions performance of electrical and electronic equipment. The test helps ensure that equipment does not adversely affect other onboard systems and complies with electromagnetic compatibility (EMC) requirements, supporting reliable operation of near-field devices and power circuits across the platform.

Purpose of the RE101 Test Objective

  • Minimize platform-level interference by evaluating low-frequency magnetic field emissions.
  • Confirm compliance with electromagnetic compatibility (EMC) requirements.
  • Support reliable operation of near-field devices and power circuits across the platform.

Scope of the RE101 Test Scope

  • Applicable to military equipment with AC and DC power lines, as well as other electronic systems.
  • Tests are performed under normal operating conditions of the equipment.
  • Frequency ranges and limit values defined in MIL-STD-461 revisions E, F, and G are applied.

RE101 Test Method Process

  • Magnetic field measurements are performed in the immediate vicinity of the equipment.
  • Field strength is recorded using antennas and probe systems.
  • Normal operating functions of the equipment are observed during the test.
  • Measurement results are compared against the applicable standard limit values.

Our RE101 Testing Services and Infrastructure STEST

  • We conduct RE101 magnetic field emissions tests in accordance with MIL-STD-461 revisions E, F, and G in our TÜRKAK-accredited laboratory, certified with TS EN ISO/IEC 17025.
  • Tests are executed using configurations aligned with platform and project requirements, based on the methods defined by the standard.
  • RE101 testing is performed in our semi-anechoic test room under the measurement conditions required by military standards.

At STEST, we perform RE101 magnetic field emissions tests under the scope of MIL-STD-461 within our accredited infrastructure, ensuring the measurement conditions required by military standards.

REQUEST A TEST APPOINTMENT
RE101 Testi

EMI/EMC Test Chamber Features

Technical Specification
EMC-1
EMC-2
EMC-3
EMC-4
Unit of Measurement
Width
7000
13000
7250
9000
mm
Length
6000
10000
4000
5500
mm
Height
3850
9000
2850
5000
mm
Door Dimensions
2000×1000
4200×4750
1950×950
2000×2000
mm
Turntable Diameter
-
6000
-
2000
mm
Turntable Load Capacity
-
70
-
2
ton
Reflection
Fully Anechoic
Semi-Anechoic
Semi-Anechoic
Semi-Anechoic
-
MIL-STD-461E Standard
Legacy electromagnetic compatibility (EMC) requirements used for older military systems and comparative evaluations.
Download PDF
MIL-STD-461F Standard
Defines EMC test methods and requirements for military and aerospace electronic systems.
Download PDF
MIL-STD-461G Standard
The latest military standard specifying updated electromagnetic compatibility (EMC) test requirements and limit values.
Download PDF