STEST

ELECTROSTATIC DISCHARGE (ESD) TEST

Aviation Environmental Conditions

RTCA DO-160 Electrostatic Discharge (ESD) Test / Part 25.0

The RTCA DO-160 Environmental Conditions and Test Procedures for Airborne Equipment standard is designed to simulate the environmental conditions that electrical and electronic equipment used in the aviation industry may encounter during flight operations. The Electrostatic Discharge (ESD) Test is defined in Part 25 of this standard and is performed to evaluate the potential effects that may occur when static electricity is suddenly discharged into a device.

Objective Purpose

  • To determine the response of electronic equipment to ESD events resulting from the sudden discharge of static electricity.
  • To support compliance assessment aimed at improving the reliability of airborne equipment.

Test Scope Coverage

  • Application of ESD pulses to various sections, interfaces, and cabling of the equipment.
  • Evaluation of the equipment’s susceptibility to disturbance and potential damage under ESD exposure.

Technical Implementation Process

  • Tests are performed by applying high-voltage pulses using a purpose-built Electrostatic Discharge (ESD) generator.
  • By applying ESD pulses at different points, the equipment response and susceptibility behavior are characterized.

Applications Use Cases

  • Electrical and electronic equipment used in aircraft and other airborne platforms.
  • Systems and interfaces within the aviation industry that may be exposed to ESD conditions.

At our STEST facility in Ankara, accredited by TURKAK, we perform the Electrostatic Discharge (ESD) Test in accordance with TS EN ISO/IEC 17025, within the scope of the RTCA DO-160 Environmental Conditions and Test Procedures for Airborne Equipment standard (versions E/F/G). For your Environmental, EMI/EMC, and ATP testing needs to enhance the quality and reliability of your products, please contact us.

REQUEST A TEST APPOINTMENT

EMI/EMC Test Chamber Features

Technical Specification
EMC-1
EMC-2
EMC-3
EMC-4
Unit of Measurement
Width
7000
13000
7250
9000
mm
Length
6000
10000
4000
5500
mm
Height
3850
9000
2850
5000
mm
Door Dimensions
2000×1000
4200×4750
1950×950
2000×2000
mm
Turntable Diameter
-
6000
-
2000
mm
Turntable Load Capacity
-
70
-
2
ton
Reflection
Fully Anechoic
Semi-Anechoic
Semi-Anechoic
Semi-Anechoic
-